EasyChem 200

Multi-Parameter Discrete Analyzer
The Systea Easychem 200 is a high throughput discrete analyzer designed to increase productivity and minimize costs while analyzing water, soil, and plant tissue.
-
60 Sample Capacity
-
Up to 200 tests per hour
-
Select Individual Parameters for Each Sample
-
Fully Automated
-
Export Results to Excel, LIMS or shared drive
-
Easy to Use – No scientific background required
Easy Operation
With the Easychem 200, Worklists can be programmed in minutes.
Simply enter the sample information and select which chemistries are to be performed.
Press play and the EasyChem 200 will run unattended for up to 720 tests.


Highly Automated
The Easychem 200 offers a highly automated solution that allows operators to program their daily worklist and then leave the instrument to run unattended as they perform other duties around the laboratory.
- Start up and Shut Down
- Calibration Curves
- Pre or Post Dilutions
- QC checks
- Weight and Moisture Corrrections
- Reagent and Instrument Monitoring
- Data export
Multiple Reagent Positions
The Easychem 200 has up to 27 reagent positions. This allows for multiple chemistries to be run in parallel.
The reagent tray is refrigerated to extend the life of the reagents.
Each tests uses microliters of reagents which can be a large cost savings over traditional flow instruments or manual testing.


Calibration curves can be automatically generated from a known standard.
All calibration information is automatically saved for traceability and can be exported into reports for auditing purposes.
Cost Saving Wash Station
The Easychem 200’s integrated wash station improves throughput, reduces costs and waste and frees operator time.
After an analysis is performed, the reaction cuvette undergoes a five stage cleaning and QC check.
This eliminates the need for reusable cuvettes which can save thousands of dollars each year compared to other popular discrete analyzers.


Technical Specifications
- Sample Volume: 2-300µl, precision 1% at 10µl
- Reagent Volume: 5-350 µl, precision < 1% at 250µl
- Reaction Volume (Sample+ reagent volume, µL): 220-350
- Automatic programmable pre or post dilution for each sample
- Maximum test per hour: 200
- Main Detector: Colorimetric, temperature controlled; halogen lamp extended UV emission; automated zero settings;accuracy +/- 1% from 0 to 2.5 O.D.; linearity better than 0.5%; noise <+/- 2m Abs. At 340 nm 2.5 O.D..
- Samples Rack: Removable 60-position rack
- Reagents Rack: Removable 27-position reagent rack, fits with 27 mL reagent bottles
- Dosing Syringe: 368 microliters syringe with 0.14 l resolution; Zero automatic setting; Accuracy +/- 0.5% from 2 to 350 uL
- Washing Station : 6 dispensing needles for washing solution, 6 sucking needles, 1 drying needle, 8 washing cycles for each cuvette
- Reaction Cuvette: 80 BIONEX® cuvettes replaceable singularly, over 20.000 tests
- Reading Methods: End point: mono o bichromatic; End Point differential (Sample blank correction); Kinetic
- Dimensions: L x D x H: 60cm x 67cm x40cm
- Weight: 32kg
Water Parameters
Alkalinity
Ammonia
Boron
Calcium
Chloride
Chlorine Free
Chlorine Total
Chromium IV
Color
Copper Diss
Cyanide*
Fluoride*
Hardness
Hydrazine
Iron Diss
Lead Diss
Magnesium
Monochloramine
Nickel Diss
Nitrate
NO2 + NO3
Nitrite
TN (persulfate)*
TN (TKN)*
Phenolics*
Phosphate
TP (TKP)*
TP (persulfate)*
Silica
Sulfide
Sulfate
Urea
Soil Parameters
Copper as Cu(I+II)- Acid-extractable
Nitrate as N-NO3 – CaCl2 extractable
Total Phosphorus as P – Kjeldahl
Iron as Fe(II+III)- Acid-extractable
Phosphorus as P-PO4 -CaCl2 extractable
Magnesium as Mg(II)
P (BSES-P) as P-PO4 -Acid extractable
Silicon as Si – CaCl2 extractable
Phosphorus as P-PO4–Olsen extractable
Silicon as Si – Acid extractable
Sulphate as SO42- – CaCl2 extractable
Phosphorus as P-PO4 – Sorption
Zinc as Zn(II)- Acid extractable
Calcium as Ca(II)
Total Kjeldahl Nitrogen as N-NH3
Phosphorus (Bray) as P-PO4 – Available
Colwell-extractable P as P-PO4
Total Protein Ammonia as N-NH3- CaCl2 extractable
Ammonia as N-NH3 – KCl extractable
Chloride as Cl- – Water extractable
Boron as B(III) -CaCl2 extractable
Nitrate as N-NO3 – KCl extractable
Nitrate as N-NO3 – Water extractable